The CUBLOC CB210 has 20 digital I/O ports, and 6 of them can be used as A/D input.
It can be connected to PC via USB for downloading and debugging.
There are two power supply options: External 9V power supply, and 5V USB power. A switch is provided to select the power source.
Only PWMs 3, 4, and 5 are available. You cannot use PWM 0, 1, and 2.
You can use ports 0 ~ 13 and 16 ~ 21 for digital I/O.
You can use ports 16 ~ 21 for A/D input, but you must first configure the ports as input ports. For A/D input, you should supply 3.3V-5V power to AVREF port.
The CB210 cannot handle currents over 300mA.
An LED is connected to port 30.
Name | I/O | Description |
RST | Reset | |
VIN | Power Input | 5V~12V Input Power |
3.3V | Power Output | 3.3V 500mA Max. |
5V | Power Output | 5V 500mA Max. |
AREF | ADC reference voltage | |
P0 | I/O | |
P1 | I/O | |
P2 | I/O | |
P3 | I/O | PWM3 |
P4 | I/O | PWM4 |
P5 | I/O | PWM5 |
P6 | I/O | |
P7 | I/O | |
P8 | I/O | |
P9 | I/O | |
P10 | I/O | |
P11 | I/O | |
P12 | I/O | |
P13 | I/O | |
P14 | I/O | |
P15 | I/O | |
P16 | I/O | ADC0 : AD Channel 0 |
P17 | I/O | ADC1 : AD Channel 1 |
P18 | I/O | ADC2 : AD Channel 2 |
P19 | I/O | ADC3 : AD Channel 3 |
P20 | I/O | ADC4 : AD Channel 4 |
P21 | I/O | ADC5 : AD Channel 5 |