Line 1: Line 1:
-====== ​MD-ADIN4 ( AD Input Module ​======+====== ​4-Channel Analog to Digital ​Input Module: MD-ADIN4 ​======
  
-^Output Value ^Resolution ^Precision ^Conversion Speed^ 
-|0 ~ 10,000 |13.30bit| ±0.1% |30ms per channel| 
  
 The AD Input Modules can be wired to read voltage sources or current sources. The AD Input Modules can be wired to read voltage sources or current sources.
  
-{{ :​modport:​md-adin4:​md-adin4.png?​700 |}}+{{ :​modport:​md-adin4:​md-adin4.png?​600 |}}
  
 When reading voltages sources, the modules can be configured for a 0 ~ 10V range or a 1 ~ 5V range using the dipswitch on the side of the module. When reading voltages sources, the modules can be configured for a 0 ~ 10V range or a 1 ~ 5V range using the dipswitch on the side of the module.
Line 15: Line 13:
  
 {{ :​modport:​md-adin4:​dipswitch.png?​nolink |}} {{ :​modport:​md-adin4:​dipswitch.png?​nolink |}}
- 
- 
  
 ===== Specification ===== ===== Specification =====
-^Item ^Description^ +^ Item                   ​^ Description ​                                                                     ^ 
-|Operating Temperature |-10 ~ 50 (no condensation)| +| Channels ​              | 4                                                                                | 
-|Operating Humidity|35 ~ 85%RH| +| Operating Temperature ​ | -10 ~ 50 (no condensation) ​                                                      ​
-|Input Resistance |20K ohms| +| Operating Humidity ​    ​| 35 ~ 85%RH                                                                       ​
-|Input Voltage Range |1~5V mode: 0.5 ~ 5.5V (Single-ended) \\ 0~10V mode: -0.5 ~ 10.5V (Single-ended)| +| Input Resistance ​      ​| 20K ohms                                                                         ​
-| Output Value           | 0 ~ 100,000                                                                      +| Input Voltage Range    | 1~5V mode: 0.5 ~ 5.5V (Single-ended) \\ 0~10V mode: -0.5 ~ 10.5V (Single-ended) ​ 
-| Resolution ​            ​| ​16.6-bit                                                                         |+| Output Value           | 0 ~ 10,000                                                                       ​
 +| Resolution ​            ​| ​13.3-bit                                                                         |
 | Precision ​             | ±0.1% ​                                                                           | | Precision ​             | ±0.1% ​                                                                           |
-| Conversion Speed       ​| ​240ms per channel ​                                                               |+| Conversion Speed       ​| ​30ms per channel ​                                                                ​|
 | Communication Method ​  | RS485                                                                            | | Communication Method ​  | RS485                                                                            |
 | Packet Transmission ​   | 3ms                                                                              | | Packet Transmission ​   | 3ms                                                                              |
 | Isolation Method ​      | No Isolation ​                                                                    | | Isolation Method ​      | No Isolation ​                                                                    |
 +
 +
 +
  
 **Important**:​ The AD Input Modules'​ inputs are not isolated, so please be sure to not provide voltage or current in excess of the specified ranges. Doing so could cause permanent damage. **Important**:​ The AD Input Modules'​ inputs are not isolated, so please be sure to not provide voltage or current in excess of the specified ranges. Doing so could cause permanent damage.
Line 69: Line 69:
 ^Channel ^0 ^1 ^2 ^3 ^ ^Channel ^0 ^1 ^2 ^3 ^
 |Starting Address(base 10) | 100 | 101 | 102 | 103 | |Starting Address(base 10) | 100 | 101 | 102 | 103 |
-|Starting Address(base 16) |  64 | 65 | 66 | 67 | +|Starting Address(base 16) | 64 | 65 | 66 | 67 | 
-|Address (base 10) used by HMI (SCADA) | 00101 00102 00103 00104 |+|Address (base 10) used by HMI (SCADA) | 40101 40102 40103 40104 |
 ===== Module ID (Modbus Slave Address) Assignment ===== ===== Module ID (Modbus Slave Address) Assignment =====
  
Line 76: Line 76:
  
 Rotary switch position 0 corresponds to Modbus slave address 10. If the ID is changed after the module is powered on, it must be power cycled for the new ID to take effect. Rotary switch position 0 corresponds to Modbus slave address 10. If the ID is changed after the module is powered on, it must be power cycled for the new ID to take effect.
 +
 +[[modport:​index|MODPORT]]