- | ====== MD-ADIN4 ( AD Input Module ) ====== | + | ====== 4-Channel Analog to Digital Input Module: MD-ADIN4 ====== |
- | ^Output Value ^Resolution ^Precision ^Conversion Speed^ | ||
- | |0 ~ 10,000 |13.30bit| ±0.1% |30ms per channel| | ||
The AD Input Modules can be wired to read voltage sources or current sources. | The AD Input Modules can be wired to read voltage sources or current sources. | ||
- | {{ :modport:md-adin4:md-adin4.png?700 |}} | + | {{ :modport:md-adin4:md-adin4.png?600 |}} |
When reading voltages sources, the modules can be configured for a 0 ~ 10V range or a 1 ~ 5V range using the dipswitch on the side of the module. | When reading voltages sources, the modules can be configured for a 0 ~ 10V range or a 1 ~ 5V range using the dipswitch on the side of the module. | ||
Line 15: | Line 13: | ||
{{ :modport:md-adin4:dipswitch.png?nolink |}} | {{ :modport:md-adin4:dipswitch.png?nolink |}} | ||
- | |||
- | |||
===== Specification ===== | ===== Specification ===== | ||
^ Item ^ Description ^ | ^ Item ^ Description ^ | ||
+ | | Channels | 4 | | ||
| Operating Temperature | -10 ~ 50 (no condensation) | | | Operating Temperature | -10 ~ 50 (no condensation) | | ||
| Operating Humidity | 35 ~ 85%RH | | | Operating Humidity | 35 ~ 85%RH | | ||
Line 31: | Line 28: | ||
| Packet Transmission | 3ms | | | Packet Transmission | 3ms | | ||
| Isolation Method | No Isolation | | | Isolation Method | No Isolation | | ||
+ | |||
+ | |||
+ | |||
**Important**: The AD Input Modules' inputs are not isolated, so please be sure to not provide voltage or current in excess of the specified ranges. Doing so could cause permanent damage. | **Important**: The AD Input Modules' inputs are not isolated, so please be sure to not provide voltage or current in excess of the specified ranges. Doing so could cause permanent damage. | ||
Line 69: | Line 69: | ||
^Channel ^0 ^1 ^2 ^3 ^ | ^Channel ^0 ^1 ^2 ^3 ^ | ||
|Starting Address(base 10) | 100 | 101 | 102 | 103 | | |Starting Address(base 10) | 100 | 101 | 102 | 103 | | ||
- | |Starting Address(base 16) | 64 | 65 | 66 | 67 | | + | |Starting Address(base 16) | 64 | 65 | 66 | 67 | |
- | |Address (base 10) used by HMI (SCADA) | 00101 | 00102 | 00103 | 00104 | | + | |Address (base 10) used by HMI (SCADA) | 40101 | 40102 | 40103 | 40104 | |
===== Module ID (Modbus Slave Address) Assignment ===== | ===== Module ID (Modbus Slave Address) Assignment ===== | ||
Line 76: | Line 76: | ||
Rotary switch position 0 corresponds to Modbus slave address 10. If the ID is changed after the module is powered on, it must be power cycled for the new ID to take effect. | Rotary switch position 0 corresponds to Modbus slave address 10. If the ID is changed after the module is powered on, it must be power cycled for the new ID to take effect. | ||
+ | |||