- | ====== MD-DAOUT2B - 2 Channel Digital to Analog Current Output Module ====== | + | ====== 2-Channel Digital to Analog Current Output Module: MD-DAOUT2B ====== |
The MD-DAOUT2B is a 2-channel digital to analog current, 0~20mA / 4~20mA , output module. The current range is configured using the dipswitch on the side of the module | The MD-DAOUT2B is a 2-channel digital to analog current, 0~20mA / 4~20mA , output module. The current range is configured using the dipswitch on the side of the module | ||
Line 7: | Line 7: | ||
- | {{ :modport:md-daout2b:md-daout2b.png?700 }} | + | {{ :modport:md-daout2b:md-daout2b.png?550 }} |
===== Specification ===== | ===== Specification ===== | ||
- | ^ Item ^ Description ^ | + | ^ Item ^ Description ^ |
- | | Operating Temperature | -10 ~ 50℃ (no condensation) | | + | | Channels | 2 | |
- | | Operating Humidity | 35 ~ 85%RH | | + | | Operating Temperature | -10 ~ 50℃ (no condensation) | |
- | | Input Resistance | 20KΩ | | + | | Operating Humidity | 35 ~ 85%RH | |
+ | | Input Resistance | 20KΩ | | ||
| Analog Output | 0~20mA Or 4~20mA (600Ω or higher differential load) | | | Analog Output | 0~20mA Or 4~20mA (600Ω or higher differential load) | | ||
- | | Output Value | 0 ~ 60,000 | | + | | Output Value | 0 ~ 60,000 | |
- | | Conversion Speed | 30ms per channel | | + | | Conversion Speed | 30ms per channel | |
- | | Communication Method | RS485 | | + | | Communication Method | RS485 | |
- | | Maximum Conversion Rate | 0 ~ 60,000, 600ms | | + | | Maximum Conversion Rate | 0 ~ 60,000, 600ms | |
- | | Isolation Method | No Isolation | | + | | Isolation Method | No Isolation | |
===== Output Current ===== | ===== Output Current ===== | ||
Line 42: | Line 43: | ||
Rotary switch position 0 corresponds to Modbus slave address 10. If the ID is changed after the module is powered on, it must be power cycled for the new ID to take effect. | Rotary switch position 0 corresponds to Modbus slave address 10. If the ID is changed after the module is powered on, it must be power cycled for the new ID to take effect. | ||
+ | |||